-8-
first time after install you would see a blank screen. This issue has been resolved.
Reference Number: 1122
SOME CONSOLE-MODE INSTALLATIONS DO NOT WORK USING WINDOWS REMOTE
DESKTOP
Prior to 4.0.0 it was not possible to install Cygwin in a virtual server using Windows
RDP. This issue has been resolved in this release.
Reference Number: 1184
ADD A NEW ETHERNET NIC REQUIRES A NODE REBOOT
With Release 4.0.0, it is no longer necessary to delete, then add, and then redis-
cover a new Ethernet NIC added to a server.
Reference Number: 2010
MULTIPLE VIRTUAL NICS IN LINUX VIRTUAL SERVER REQUIRES MANUAL CONFIGURATION
Workaround:
1. When you add multiple virtual NICs to a RedHat virtual server, copy and edit
/etc/sysconfig/network-scripts/ifcfg-eth0
to add the additional device.
2. For a SLES virtual server, run yast and in the network devices configuration,
select Other to bring up the interface configuration and enter the correct eth
number.
This workaround has been added to the Virtualization Manager Administration
Guide, Chapter 7.
Reference Number: 2013
VIRTUALIZATION MANAGER DOES NOT SEE LOCAL DRIVES WITH SMART FEATURES
It is not longer necessary to disable SMART in the node's BIOS for the disks to be
accessible.
Reference Number: 2064
SINGLE SERVER EDITION INSTALL FAILSUNABLE TO FIND THE INSTALLATION MEDIA
In previous releases, if you installed Single Server Edition systems with a USB
CDROM drive and had USB2 enabled in the BIOS, you would see the message:
“Unable to find the installation media. This release now supports the EHCI (USB
2.0) controller.
Reference Number: 2433